Noisy Environment? Not a Problem
Ultrasound Leak Detector Solutions
CTRL Systems has designed an easy-to-use device that is more sensitive than any other ultrasound detector in the world. With the UL101 Leak Detector and our conditioned based monitoring technology, you can detect leaks from up to 150 feet away and pinpoint their exact location in mere seconds. The UL101 Leak Detector is not affected by loud industrial environments and can be used in windy conditions. It can be used to locate any type of turbulent compressed gas or vacuum leak. Applications include: compressed air energy swings (reduce compressor usage by 20-30%!), vacuum leak detection, HVAC leak detection, dry sprinkler inspection, steam system inspection, cabin testing, and many more!
Ultrasonic Leak Detector Benefits
Other devices require you to be within 1 to 2 feet, to adjust the frequency, to only use for a particular type of gas, etc. The design of the UL101 is “keep it simple.” CTRL has designed an easy to use device that is more sensitive than any other and fits in the palm of your hands.
With the UL101 Leak Detector, you can easily find leaks in a noisy environment. Acoustic ultrasound has a very impressive range and can detect leaks from as far as 150 feet, depending upon the intensity of the leak, pinpointing the leak to the exact location in seconds. For more information and product specifications, see the related products below.
-
- Most Sensitive – Detects all turbulent (non-laminar) flow leaks
- No Calibration – Indicate & locate; no need to measure
- Best Signal-to-Noise – Less internal white noise than all other detectors
- Easy To Use – No need to adjust frequency or application settings
Energy Savings
HVAC
Expensive Gas (Any Type)
Steam Leaks/Steam Traps
Energy Savings
Reduce your compressor usage by 20% – 30%.
HVAC
Ultrasound is not affected by wind.
Expensive Gas (Any Type)
Finding one Nitrogen leak has immediate ROI.
Steam Leaks/Steam Traps
Improve steam system efficiency and save money.
https://www.youtube.com/watch?v=crv4bT_bBlchttps://www.youtube.com/watch?v=QT5Zz3ZzAmo
CASE STUDY
An oil/gas refinery tests and standardizes the UL101 and PowerBeam for unit operations and startup N2 purge leak detection. The ultrasound detector was able to quickly indicate nitrogen leaks on flanges without removing the insulation.
| No need to use soap & bubbles.
| No need to remove insulation.
| No need to build scaffolding to reach the flanges for testing.
35
psig
Nitrogen
0
Flanges
# Tested in 1 Day
0
Week
Time Savings